Chemcote Water and Utilities Coating Solutions
Advanced Anti-Corrosion, Potable Water Approved and Infrastructure Refurbishment Coatings for Water Utilities & Local Authorities
Protecting municipal water supply, sewerage treatment and drainage infrastructure requires specialised engineering coating systems capable of withstanding constant immersion, biogenic sulphuric acid attack, abrasive slurries and stringent potable water safety standards. Critical utility assets including raw water pumps, aerobic reactors, potable water valves, pool filtration vessels, thickeners, clarifiers and concrete chemical bunds face rapid pitting corrosion, metallic salt contamination, crevice attack and concrete spalling. Without advanced surface protection, these harsh operating environments compromise water quality, reduce hydraulic pumping efficiency and lead to premature infrastructure replacement.
Chemcote provides Australian-owned protective coating applications, NACE and ACA certified inspections, design specifications and asset refurbishment services across Australia. Servicing major authorities including Sydney Water, Melbourne Water and regional water utilities, Chemcote deploys high-performance vinyl ester glassflakes, potable water approved linings, wet-tolerant epoxies and concrete repair systems to extend asset service life while reducing power consumption and operational expenditure.
The Water & Utilities Corrosion Challenge
Operating water supply networks and sewage treatment plants presents distinct chemical, mechanical and environmental hurdles:
Reduced Pumping Efficiency & Power Losses: Decades of corrosion and surface roughness inside split-case cast iron pumps increase hydraulic friction, driving up power consumption and carbon emissions.
Deep Metallic Salt Contamination: Cast iron pumps and steel vessels in service for 20+ years accumulate deep metallic salts within the corroded matrix, causing premature coating failure if not properly heat-treated and decontaminated.
High Humidity & Dew Point Application Barriers: Tank interiors and aerobic reactor floors suffer from continuous moisture and high humidity during maintenance, making conventional coatings that require dry substrates impractical or costly due to dehumidification setups.
Chemical Attack in Wastewater & Water Treatment: Exposure to biogenic gases, chlorine, hot caustic, brine and sulphuric acid rapidly degrades unlined concrete bunds and steel filter vessels, creating leak paths and ground contamination risks.
Why Chemcote? The Technology Advantage
Chemcote shifts the maintenance paradigm by deploying surface and moisture-tolerant epoxies, low-friction glassflake vinyl esters and certified potable water coating systems. Our specialised technologies eliminate costly dehumidification setups, lower energy consumption through composite fluid efficiency and allow rapid turnaround times without compromising asset longevity.
CONVENTIONAL UTILITY PAINTS
- Requires Dry Abrasive Blasting & Dehumidification
- High Hydraulic Drag Drives Up Energy Costs
- Fails Over Un-treated Salt-Contaminated Substrates
- Prone to Crevice Corrosion at Flange Faces
- Extended Production Downtime
CHEMCOTE ADVANCED SYSTEMS
- Moisture & Wet Substrate Tolerant (No Dehumidification)
- Ultra-Smooth Composite Finish Reduces Friction & Power Draw
- Full Decontamination & Salt Removal Protocols (<25ppm)
- Machined Flange Rebates Prevent Crevice Attack
- Rapid Cure & Return to Service (3-Day Turnaround)
Key Technical Benefits
1. Fluid Efficiency & Energy Cost Reduction
By applying ultra-smooth glassflake vinyl esters (Chem-tect RB 300 GL) inside raw water split-case pumps, hydraulic friction is drastically reduced, lowering energy consumption and delivering full refurbishment payback in as little as 14 months.
Potable Water Approved & High Chemical Resistance
Our range includes certified potable water linings (PPG Amerlock 400) and heavy-duty vinyl esters (Chem-tect RB 300 series) that withstand aggressive water treatment chemicals, chlorine and pH levels from 0 to 13.
3. Moisture-Tolerant Application Without Dehumidification
Using wet-tolerant systems (Epo-Chem RS 500P & RA 500), large aerobic reactor floors and tank interiors can be coated in high humidity without dew point delays or expensive dehumidification equipment, keeping project costs to a minimum.
4. Flange Rebating & Crevice Corrosion Prevention
Precision machining of rebates on flanged faces allows protective glassflake coatings to extend seamlessly across mating surfaces, eliminating gasket misalignment and stopping crevice corrosion permanently.
Specialised Water & Utilities Solutions
1. Raw Water & Treated Water Split-Case Pump Refurbishment
Overhauling heavily corroded cast iron pump bodies and bronze impellers. Incorporating heat treatment, hot washing salt decontamination (<25ppm), gland packing area rebuilding, critical dimension protection and low-friction topcoats to restore peak operating efficiency.
2. Aerobic Reactor, Thickener and Clarifier Tank Linings
Internal re-lining of concrete and steel aerobic reactors, thickeners and clarifier tanks. Applied directly over damp, water-jetted substrates using Epo-Chem RS 500P and RA 500 to deliver an expected service life in excess of 15 years.
3. Potable Water Valves & Pipeline Infrastructure
Mechanical and coating refurbishment of potable water valve bodies, discs and spillway gate assemblies. Utilising pit-filling epoxies (Epo-Chem RS 500PF) and multi-layer internal protective linings to ensure C2 to C5 environment durability.
4. Pool Filtration Vessels & Chlorine Plant Chemical Bunds
Refurbishing municipal pool filter vessels, tube plates and chemical containment bunds. Restoring spalling concrete bunds exposed to sulphuric acid, caustic and chlorine with smart colour-changing leak detection coatings.
Why Chemcote? The Technology Advantage
Chemcote shifts the maintenance paradigm by deploying solvent-free, wet, rust and oil-tolerant coating technology. Unlike conventional paints, our systems do not require clinically dry or perfectly blast-cleaned steel.
SURFACE PREPARATION
- Ultra High Pressure Water Jetting (UHP)
- Heat Treatment & Thermal Salt Decontamination
- Abrasive Blasting & Flange Rebate Machining
SPECIFICATION & INSPECTION
- NACE & ACA Certified Coating Inspectors
- Solvent Wiping, Salt Testing (<25ppm) & Cleanliness Checks
- Full QA Spark Testing (8kV) & Dry Film Thickness Checks
COATINGS APPLICATION
- Potable Water Certified Vessel & Valve Linings
- Split-Case Pump Volute & Impeller Composite Rebuilding
- Aerobic Reactor & Concrete Bund Protection
Marine Assets Protected
Asset Category
Specific Applications
Coating System
Water Extraction & Pumping
Raw Water Split-Case Pumps, Treated Water Pumps, Impellers, Wear Ring Lands, Gland Areas
Chem-tect RB 332 Corrosion Barrier & RB 300 GL Fluid Efficiency Topcoat
Water Treatment & Filtration
Potable Water Valves, Discs, Pool Filter Vessels, Tube Plates, Spigot Outlets
PPG Amerlock 400 Internals, Epo-Chem RS 500PF Pit-Filler & Weathermax Topcoat
Wastewater & Sewerage
Aerobic Reactors, Thickeners, Clarifiers, Spillway Gates, Channels, Digesters
Epo-Chem RS 500P Mio Primer & Epo-Chem RA 500 Moisture-Tolerant Topcoat
Chemical Containment
Chlorine Plant Bunds, Acid Containment, Pump Plinths, Walkways, Storage Tanks
Chem-deck, Damp-Crete RH 800, Epo-Chem RF 500 & Hot-Cote RD 900
CASE STUDIES
Check out some of the projects we’ve worked on.






Download Our Water Supply & Local Authority Brochure
Gain complete technical specifications, application guides and performance data for our municipal water, sewerage and utility protective systems.
Frequently Asked Questions
How does Chemcote's pump coating system reduce municipal power consumption?
Severe internal corrosion creates rough surface profiles inside pump bodies, causing fluid turbulence and high friction. By applying Chem-tect RB 300 GL glassflake vinyl ester, we create an ultra-smooth, low-friction composite barrier that optimises fluid flow dynamics, reducing electrical energy draw and earning carbon credits.
How does Chemcote decontaminate metallic salts in old cast iron water pumps?
Pumps in long-term raw water service absorb deep metallic salts within cast iron pores. We perform thermal heat treatment followed by multiple rounds of hot washing and re-abrasive blasting to drive out trapped chlorides, ensuring salt levels drop below 25ppm before coating application to guarantee long-term adhesion.
Can Chemcote coat aerobic reactors and wastewater tanks without dehumidification?
Yes. Our Epo-Chem RS 500P and RA 500 coating systems feature wet-tolerant formulation properties. They can be applied directly over damp substrates in high humidity environments without worrying about dew point restrictions, eliminating expensive dehumidification equipment costs.
Why are flange faces rebated before applying Chemcote protective coatings?
Uncoated flange faces or misaligned gaskets allow moisture to seep between mating metal surfaces, causing severe crevice corrosion. We precision-machine shallow rebates into all flange faces prior to coating, allowing the vinyl ester lining to cover the gasket face completely and seal out fluid ingress.