Search
Close this search box.

Column Pump Composite Repairs

OVERVIEW:    Chemcote were approached to improve corrosion resistance and improve fluid flow efficiency for this Power Generation Customer’s cast iron column pump

INDUSTRY

ENVIRONMENT

Ambient Salt Water

SUBSTRATE

Cast Iron Column Pump

CHALLENGE

Chemcote were brought in to carry out pump refurbishment after catastrophic failure of bearing causing the impeller to wear through the casing of the column pump

SOLUTION

Refurbish pump lining to extend service life using glass flake filled coatings, then top coated using RP 500 to improve fluid flow efficiency

SCOPE

Abrasive blast to AS.1627.4 to class 2.5

Masking and protection of critical tolerances and bush area on flange.

Pit filled to allow smooth transition and prevent coating defects

Sand smooth where necessary & application of RB364 to 1,000µm

Internal & external holiday testing to ensure coating continuity using the required voltage to suit the dry film thickness.

Application of the top coat Ceram-chem™ RP 500

PRODUCTS

Internals

Chem-tect™ RB 364 a glass flake filled vinyl ester

Ceram-chem™ RP 500 a ceramic filled epoxy

Externals

Epo-Chem™ RS 500P a surface and moisture tolerant primer

Epo-chem™ RA 500M a glass flake filled epoxy

OUTCOME

Improved corrosion resistance and fluid flow efficiency through the quality assurance process employed by Chemcote

RELATED CASE STUDIES

Base Plate Corrosion Prevention

Repairs required Application of Primer Coating applied to affected areas After application of Topcoat Previous Next OVERVIEW:    A 40 year old excess gas bleeder structure

Read More »

Industrial Fallout Protection

After whip abrasive blasting Application of Epo-chem system to internals Basalt Fibre application on internals OVERVIEW:    A steel production plant contracted Chemcote to reinforce

Read More »
Contact Our Specialist Coating Advisors