



OVERVIEW: This Power Generation customer approached Chemcote to save an estimated replacement cost of $500K for this 20 year old Bronze tube sheet.
This refurbishment is expected to extend the life for another 20 years, and corrosion protection has been provided to ancillary equipment.

INDUSTRY
ENVIRONMENT
40-60°C, sea water
SUBSTRATE
20 Year Old – Bronze tube sheet
CHALLENGE
To provide a long term solution for the corroded tube ports and tube sheet
SOLUTION
A glass flake filled vinyl ester was applied to provide excellent permeation resistance and high dielectric strength
SCOPE
Tube internals were protected by inserting specially ordered silicon plugs to prevent abrasive blasting from damaging wall thickness. Abrasive blast as per required standard and remove silicon plugs and glue nylon tube inserts into position and then pitfill all deep cavities using RB 300 Series. We used the proprietary method to obtain a flat surface using RB 300 Series.
PRODUCTS
Chem-tect™ RB 364 a glass flake filled vinyl ester, provides excellent permeation resistance and high dielectric strength.
OUTCOME
Chemcote’s solution has extended the life of this asset by 12-24 months, and delivered a 30% improvement in functioning. Continuous high performance is guaranteed until our review at the next planned outage.
RELATED CASE STUDIES
Deliver Efficiency through Protective Coatings
Energy loss, efficiency drops, and wear from corrosion or erosion can cost thousands in electricity anddowntime. Chemcote Specialty Coatings provides high-performance ceramic and glassflake solutionsthat
Valve Paddles Anti-Corrosion Repairs
Paddle Before Coating After Blasting and First Coat Casting to fine tolerance after reassembly on site Coating complete Overview: Chemcote successfully restored steel outlet and
Beach Front House Corrosion Protection
Scaffold Installation Corrosion condition on Arrival During Application Steel awaiting Topcoat Beach house inspection after 2 Years Overview: Beach front house homeowner was looking for