OVERVIEW: The 8 year old pump had dropped off in efficiency due to the combination of corrosion erosion and mechanical fatigue. This was due to a poorly specified and applied coating which was delaminating allowing corrosion to exist.
INDUSTRY
ENVIRONMENT
River Water
SUBSTRATE
Cast iron body
CHALLENGE
The pump had dropped off in efficiency due to the combination of corrosion erosion and mechanical fatigue. This was due to a poorly specified and applied coating which was delaminating allowing corrosion to exist.
SOLUTION
After 8 years in service the substrate was corroded and heavily contaminated with metallic salts. Treatment using a combination of methods including abrasive blasting, hot washing and acid washing to reduce salts below 25ppm. We then recommended the application of 2 coats of Chem-tect™ RB 364; a glass flake filled vinyl ester providing an excellent corrosion barrier and long term protection. We then applied 2 coats of Epo-chem™ RP 500 to enhance fluid efficiency in turn reducing power consumption.
SCOPE
Strip and assess
Manufacture template to ensure mating faces match
Grind chamfer on all flanged faces, allowing the coating to be applied on the flange face preventing future crevice corrosion.
Protect critical dimensions
Abrasive blast and treat to reduce metallic salts by hot washing and re-abrasive blast.
Apply corrosion barrier Chem-tect™ RB 364
QA included spark testing and DFT
Apply topcoat of Epo-chem™ RP 500
PRODUCTS
OUTCOME
By coating with Chem-tect™ RB 300 & Epo-chem™ RP 500, future corrosion erosion is prevented with a reduced amount of friction through composite technology. The pump now functions more efficiently when in use consuming less power, which led to carbon credits and a reduction of greenhouse gas emissions. The payback period of the entire refurbishment worked out to be only 14 months.
RELATED CASE STUDIES
Centrifugal Pump Corrosion Protection
Before Coating Application Strip & Assess Kevlar Application anti swirl vane Applying the 1st Coating Completed Internal Coating application OVERVIEW: Chemcote provided a long-lasting solution
Maximise Pipe Durability Using Composites
Condition Before Coating Coating to critical areas complete External coating carried out on site Externals Requiring Relining OVERVIEW: Chemcote was tasked with extending the service
Refurbishment of Basket Strainer
Strainer nearing completion Internals nearing completion Internals illustrating pit filling After abrasive blasting, pitting After fabrication repairs OVERVIEW: Chemcote provided a long term corrosion protection for