Industrial Fallout Protection

OVERVIEW:    A steel production plant contracted Chemcote to reinforce a failing 25 year old corrugated pipe located in a settling pond.

 

ENVIRONMENT

Storm water with coke fines fall out from coke basin

SUBSTRATE

25 year old corroded corrugated pipe

CHALLENGE

A confined pipe opening over a channel posed access difficulties. Our specialist crew was able to reduce abrasive media in the settling pond by encapsulating the entry point and working through a small window

SOLUTION

A moisture resistant coating which is unaffected by water and humidity during application was required.  Chemcote chose Epo-chem™ wet and surface tolerant primer and top coat system for this project.

SCOPE

High pressure hot wash internals to remove contaminants

 

Whip abrasive blast

 

Apply 1 coat Epo-chem™ RS 500P

 

Apply 1 coat Epo-chem™ RA 500M

 

Apply basalt fibre consolidated with Epo-chem™ RA 500M

OUTCOME

Our specialist team was able to overcome the access difficulties posed by a confined opening over a channel to deliver a 2-coat barrier solution. The Epo-Chem system was ideal for this environment as it cures underwater, allowing the pipe to return to service immediately with full protection from future stormwater damage.

RELATED CASE STUDIES

Volutes Corrosion Repair

Corrosion condition before surface preparation Primer application Complex wet areas mid coat application Final Coat applied Overview: Defence subcontractor looking after scheduled maintenance on board

Read More »
Contact Our Specialist Coating Advisors