OVERVIEW: A steel production plant contracted Chemcote to reinforce a failing 25 year old corrugated pipe located in a settling pond.
INDUSTRY
ENVIRONMENT
Storm water with coke fines fall out from coke basin
SUBSTRATE
25 year old corroded corrugated pipe
CHALLENGE
A confined pipe opening over a channel posed access difficulties. Our specialist crew was able to reduce abrasive media in the settling pond by encapsulating the entry point and working through a small window
SOLUTION
A moisture resistant coating which is unaffected by water and humidity during application was required. Chemcote chose Epo-chem™ wet and surface tolerant primer and top coat system for this project.
SCOPE
High pressure hot wash internals to remove contaminants
Whip abrasive blast
Apply 1 coat Epo-chem™ RS 500P
Apply 1 coat Epo-chem™ RA 500M
Apply basalt fibre consolidated with Epo-chem™ RA 500M
PRODUCTS
OUTCOME
Our specialist team was able to overcome the access difficulties posed by a confined opening over a channel to deliver a 2-coat barrier solution. The Epo-Chem system was ideal for this environment as it cures underwater, allowing the pipe to return to service immediately with full protection from future stormwater damage.
RELATED CASE STUDIES
Air Receiver Restoration for Long-Term Durability
Pitting corrosion near shaft landing After first abrasive blasting After 2nd Abrasive blast holes were found requiring composite reinforcement Filling void in difficult to reach
High Performing Replacement for 316L SS
On inspection flange corrosion Deep pitting on forged section Application of 1st coat Ready to be put into service for 25+ years of life OVERVIEW:
Power Station Debris Filter Lining Repair
Damage to existing rubber lining Internal void to be filled in around the circumference of the screen Close up of repair area for the full