OVERVIEW: A steel production plant contracted Chemcote to reinforce a failing 25 year old corrugated pipe located in a settling pond.
INDUSTRY
ENVIRONMENT
Storm water with coke fines fall out from coke basin
SUBSTRATE
25 year old corroded corrugated pipe
CHALLENGE
A confined pipe opening over a channel posed access difficulties. Our specialist crew was able to reduce abrasive media in the settling pond by encapsulating the entry point and working through a small window
SOLUTION
A moisture resistant coating which is unaffected by water and humidity during application was required. The Epo-chem™ wet and surface tolerant primer and top coat system was chosen
SCOPE
High pressure hot wash internals to remove contaminants
Whip abrasive blast
Apply 1 coat Epo-chem™ RS 500P
Apply 1 coat Epo-chem™ RA 500M
Apply basalt fibre consolidated with Epo-chem™ RA 500M
PRODUCTS
OUTCOME
Our specialist team was able to overcome the access difficulties posed by a confined opening over a channel to deliver a 2-coat barrier solution. The Epo-Chem system was ideal for this environment as it cures underwater, allowing the pipe to return to service immediately with full protection from future stormwater damage.
RELATED CASE STUDIES
Refurbishment of Basket Strainer
Strainer nearing completion Internals nearing completion Internals illustrating pit filling After abrasive blasting, pitting After fabrication repairs OVERVIEW: Chemcote provided a long term corrosion protection for
Preventing blockages using Chemcote Solution
Condition of surface before mechanical preparation RB 364 applied to spot abrasive blasted surfaces Pugmill externals Coating with InD Cote Previous Next OVERVIEW: A
Base Plate Corrosion Prevention
Repairs required Application of Primer Coating applied to affected areas After application of Topcoat Previous Next OVERVIEW: A 40 year old excess gas bleeder structure