OVERVIEW: Chemcote’s specialist team refurbished the carbon steel self cleaning strainer back wash boxes and saving the customer fabrication time and money.
Production was not interrupted and RB 364 will provide long term protection coupled with the addition of composite reinforcement.

INDUSTRY
ENVIRONMENT
Sea Water
SUBSTRATE
Carbon steel
CHALLENGE
A short time frame due to critical power shortage stopping other major processes forced weekend work to commence. Rebuild and reinforce flanges and provide defect free corrosion protection.
SOLUTION
Remove failed coating and hot wash components. Stencil existing profiles and make a template. Pre-abrasive blast and hot wash cycle to reduce soluble salts to an acceptable level.
SCOPE
Abrasive blast Self Cleaning Strainer to AS 1627.4
Class 3 Application of RB 332 to the internals including flanges
Reinforce casting using Composite repair techniques to reinstate original strength
Holiday testing up to 12kV to detect and rectify defects
OUTCOME
Refurbishing the self cleaning strainer back wash boxes saved the customer 8 days in fabrication time and money ensuring production is not interrupted. RB 364 will provide long term protection coupled with the addition of composite reinforcement.
RELATED CASE STUDIES
Deliver Efficiency through Protective Coatings
Energy loss, efficiency drops, and wear from corrosion or erosion can cost thousands in electricity anddowntime. Chemcote Specialty Coatings provides high-performance ceramic and glassflake solutionsthat
Valve Paddles Anti-Corrosion Repairs
Paddle Before Coating After Blasting and First Coat Casting to fine tolerance after reassembly on site Coating complete Overview: Chemcote successfully restored steel outlet and
Beach Front House Corrosion Protection
Scaffold Installation Corrosion condition on Arrival During Application Steel awaiting Topcoat Beach house inspection after 2 Years Overview: Beach front house homeowner was looking for