OVERVIEW: Chemcote was engaged to provide long term protection to assets in a highly aggressive environment. Salt water mains supplying a condenser were externally corroded, and the requirement was for urgent repairs with minimal disruption to plant operation. A 20 year life extension is expected using Chemcote’s solution.
INDUSTRY
ENVIRONMENT
Industrial immersed areas
SUBSTRATE
Mild steel pipework with extensive external corrosion due to steam from pit below and salt water leaks from above
CHALLENGE
Carry out external corrosion protection to equipment in situ
SOLUTION
Apply Epo-Chem™ RS 500P @ 100 microns
Apply Epo-Chem™ RA 500M in one coat @ 350-400 microns total DFT
Apply 1 coat of Epo-Chem™ RC 500GTC Jade Green
Unmask and detail
SCOPE
Check for sharp edges and remove any weld spatter
Mechanically clean loose corrosion using needle gun and wash down
PRODUCTS
OUTCOME
Chemcote’s solution has extended the life of this asset by 12-24 months, and delivered a 30% improvement in functioning. Continuous high performance is guaranteed until our review at the next planned outage.
RELATED CASE STUDIES
Refurbishment of Basket Strainer
After fabrication repairs After abrasive blasting, pitting visible Finished 300 Series Vinyl Ester Internals nearing completion OVERVIEW: Customer required long term corrosion protection for
Duo Chek Valve
Masking and ready for abrasive blasting Application of multiple coats of RB364 internally Holiday testing to ensure coating continuity Coating complete OVERVIEW: Chemcote was
Pipe External Corrosion Protection
Existing corrosion, mech prep after UHPWB Application of spot primer Mid coat applied to affected areas After application of topcoat OVERVIEW: Chemcote was engaged