OVERVIEW: Chemcote was engaged to provide long term protection to assets in a highly aggressive environment. Salt water mains supplying a condenser were externally corroded, and the requirement was for urgent repairs with minimal disruption to plant operation. A 20 year life extension is expected using Chemcote’s solution.

INDUSTRY
ENVIRONMENT
Industrial immersed areas
SUBSTRATE
Mild steel pipework with extensive external corrosion due to steam from pit below and salt water leaks from above
CHALLENGE
Carry out external corrosion protection to equipment in situ
SOLUTION
Apply Epo-Chem™ RS 500P @ 100 microns
Apply Epo-Chem™ RA 500M in one coat @ 350-400 microns total DFT
Apply 1 coat of Epo-Chem™ RC 500GTC Jade Green
Unmask and detail
SCOPE
Check for sharp edges and remove any weld spatter
Mechanically clean loose corrosion using needle gun and wash down
PRODUCTS
OUTCOME
Chemcote’s solution has extended the life of this asset by 12-24 months, and delivered a 30% improvement in functioning. Continuous high performance is guaranteed until our review at the next planned outage.
RELATED CASE STUDIES
Beach Front House Corrosion Protection
Scaffold Installation Corrosion condition on Arrival During Application Steel awaiting Topcoat Beach house inspection after 2 Years Overview: Beach front house homeowner was looking for
Volutes Corrosion Repair
Corrosion condition before surface preparation Primer application Complex wet areas mid coat application Final Coat applied Overview: Defence subcontractor looking after scheduled maintenance on board
Centrifugal Pump Corrosion Protection
Before Coating Application Strip & Assess Kevlar Application anti swirl vane Applying the 1st Coating Completed Internal Coating application OVERVIEW: Chemcote provided a long-lasting solution