Search
Close this search box.

Pipe External Corrosion Protection

OVERVIEW:    Chemcote was engaged to provide long term protection to assets in a highly aggressive environment. Salt water mains supplying a condenser were externally corroded, and the requirement was for urgent repairs with minimal disruption to plant operation. A 20 year life extension is expected using Chemcote’s solution.

INDUSTRY

ENVIRONMENT

Industrial immersed areas

SUBSTRATE

Mild steel pipework with extensive external corrosion due to steam from pit below and salt water leaks from above

CHALLENGE

Carry out external corrosion protection to equipment in situ

SOLUTION

Apply Epo-Chem™ RS 500P @ 100 microns

Apply Epo-Chem™ RA 500M in one coat @ 350-400 microns total DFT

Apply 1 coat of Epo-Chem™ RC 500GTC Jade Green

Unmask and detail

SCOPE

Check for sharp edges and remove any weld spatter

Mechanically clean loose corrosion using needle gun and wash down

PRODUCTS

OUTCOME

Chemcote’s solution has extended the life of this asset by 12-24 months, and delivered a 30% improvement in functioning. Continuous high performance is guaranteed until our review at the next planned outage.

RELATED CASE STUDIES

Base Plate Corrosion Prevention

Repairs required Application of Primer Coating applied to affected areas After application of Topcoat Previous Next OVERVIEW:    A 40 year old excess gas bleeder structure

Read More »

Industrial Fallout Protection

After whip abrasive blasting Application of Epo-chem system to internals Basalt Fibre application on internals OVERVIEW:    A steel production plant contracted Chemcote to reinforce

Read More »
Contact Our Specialist Coating Advisors