Search
Close this search box.

Industrial Fallout Protection

OVERVIEW:    A steel production plant contracted Chemcote to reinforce a failing 25 year old corrugated pipe located in a settling pond.

 

ENVIRONMENT

Storm water with coke fines fall out from coke basin

SUBSTRATE

25 year old corroded corrugated pipe

CHALLENGE

A confined pipe opening over a channel posed access difficulties. Our specialist crew was able to reduce abrasive media in the settling pond by encapsulating the entry point and working through a small window

SOLUTION

A moisture resistant coating which is unaffected by water and humidity during application was required.  The Epo-chem™ wet and surface tolerant primer and top coat system was chosen

SCOPE

High pressure hot wash internals to remove contaminants

 

Whip abrasive blast

 

Apply 1 coat Epo-chem™ RS 500P

 

Apply 1 coat Epo-chem™ RA 500M

 

Apply basalt fibre consolidated with Epo-chem™ RA 500M

OUTCOME

Our specialist team was able to overcome the access difficulties posed by a confined opening over a channel to deliver a 2-coat barrier solution. The Epo-Chem system was ideal for this environment as it cures underwater, allowing the pipe to return to service immediately with full protection from future stormwater damage.

RELATED CASE STUDIES

Base Plate Corrosion Prevention

Repairs required Application of Primer Coating applied to affected areas After application of Topcoat Previous Next OVERVIEW:    A 40 year old excess gas bleeder structure

Read More »

Industrial Fallout Protection

After whip abrasive blasting Application of Epo-chem system to internals Basalt Fibre application on internals OVERVIEW:    A steel production plant contracted Chemcote to reinforce

Read More »
Contact Our Specialist Coating Advisors