Search
Close this search box.

Industrial Fallout Protection

OVERVIEW:    A steel production plant contracted Chemcote to reinforce a failing 25 year old corrugated pipe located in a settling pond.

 

ENVIRONMENT

Storm water with coke fines fall out from coke basin

SUBSTRATE

25 year old corroded corrugated pipe

CHALLENGE

A confined pipe opening over a channel posed access difficulties. Our specialist crew was able to reduce abrasive media in the settling pond by encapsulating the entry point and working through a small window

SOLUTION

A moisture resistant coating which is unaffected by water and humidity during application was required.  The Epo-chem™ wet and surface tolerant primer and top coat system was chosen

SCOPE

High pressure hot wash internals to remove contaminants

 

Whip abrasive blast

 

Apply 1 coat Epo-chem™ RS 500P

 

Apply 1 coat Epo-chem™ RA 500M

 

Apply basalt fibre consolidated with Epo-chem™ RA 500M

OUTCOME

Our specialist team was able to overcome the access difficulties posed by a confined opening over a channel to deliver a 2-coat barrier solution. The Epo-Chem system was ideal for this environment as it cures underwater, allowing the pipe to return to service immediately with full protection from future stormwater damage.