OVERVIEW: Maximum life expectancy was top on the list when this galvanising plant was looking for a new coating solution. We managed to save time and money during the installation of the long term solution. The customer mentioned he chose us due to our customer service during the initial contact stages of his enquiry.
INDUSTRY
ENVIRONMENT
Highly corrosive range of chemicals including Sodium Hydroxide and Hydrochloric Acid
SUBSTRATE
Concrete Bund in a chemical plant
CHALLENGE
Upon inspection, the concrete bund was identified to be in a poor condition. This is due to the existing surface deteriorating after years of exposure. There are many locations on the bund that show a degree of damage and there is also evidence of chemical pooling. This seems to indicate that the fall is not functioning properly and, therefore, needs to be addressed and reinstated
SOLUTION
To ensure that the maximum life of the coating is achieved for our client, we reviewed the environment conditions, and specified the Chemco International Glass Flake Filled Chem-tect™ 300 series coatings. These coatings have been chosen as they offer excellent chemical and corrosion protection
SCOPE
Mobilise to site
Set up of dehumidification
Follow the Chemcote Concrete Coating surface preparation and priming Procedure
Reinstate the fall, and pit fill the holes using Chem-tect™ RA 300 series:
Application of 1st coat of RA 364 over entire surface
Application of 2nd coat of RA 364 to a DFT of 1000 nominal thickness for all areas
Carry out QA testing
Demobilise from site
PRODUCTS
OUTCOME
This coating project was completed on time, to budget and an inspection after 2 years has been recommended. Our Client was pleased with the result and the service.
RELATED CASE STUDIES
Industrial Fallout Protection
After whip abrasive blasting Application of Epo-chem system to internals Basalt Fibre application on internals OVERVIEW: A steel production plant contracted Chemcote to reinforce
Fast Curing Abrasion Protection
Condition of surface before mechanical preparation RB 364 applied to spot abrasive blasted surfaces Pugmill externals Coating with InD Cote OVERVIEW: Chemcote’s specialist team
Split Case Salt Water Pump Refurbishment
Apply protection to all machined surfaces Application of 1st coat RB 364 Apply Ceram-Chem RP500 Ready to return to service for another 15+ years of