OVERVIEW: Chemcote’s specialist team refurbished the carbon steel self cleaning strainer back wash boxes and saving the customer fabrication time and money.
Production was not interrupted and RB 364 will provide long term protection coupled with the addition of composite reinforcement.
INDUSTRY
ENVIRONMENT
Sea Water
SUBSTRATE
Carbon steel
CHALLENGE
A short time frame due to critical power shortage stopping other major processes forced weekend work to commence. Rebuild and reinforce flanges and provide defect free corrosion protection.
SOLUTION
Remove failed coating and hot wash components. Stencil existing profiles and make a template. Pre-abrasive blast and hot wash cycle to reduce soluble salts to an acceptable level.
SCOPE
Abrasive blast Self Cleaning Strainer to AS 1627.4
Class 3 Application of RB 332 to the internals including flanges
Reinforce casting using Composite repair techniques to reinstate original strength
Holiday testing up to 12kV to detect and rectify defects
OUTCOME
Refurbishing the self cleaning strainer back wash boxes saved the customer 8 days in fabrication time and money ensuring production is not interrupted. RB 364 will provide long term protection coupled with the addition of composite reinforcement.
RELATED CASE STUDIES
Fast Curing Abrasion Protection
Condition of surface before mechanical preparation RB 364 applied to spot abrasive blasted surfaces Pugmill externals Coating with InD Cote OVERVIEW: Chemcote’s specialist team
Split Case Salt Water Pump Refurbishment
Apply protection to all machined surfaces Application of 1st coat RB 364 Apply Ceram-Chem RP500 Ready to return to service for another 15+ years of
Composite Pipe Repair
Flange is barely attached Repairs commence Repairs using composite weave mat Coating complete OVERVIEW: A power station client required corrosion protection for a 30-plus