OVERVIEW: This cast iron, recirculated water heat exchanger vessel from 1981 was exposed to inclement weather and experiencing fatigue cracking in some welds and localised corrosion on the tube bundle guides. The Epo-chem™ system will with provide long term protection in this environment.
INDUSTRY
ENVIRONMENT
Recirculated water
SUBSTRATE
Cast Iron
CHALLENGE
This heat exchanger vessel was manufactured in 1981 and installed shortly after. Fatigue cracking was found in some welds and localised corrosion was discovered on the tube bundle guides. The unit was exposed to inclement weather.
SOLUTION
We recommended coating with our moisture and surface tolerant epoxy RS 500P as a primer. Finishing with a top coat of RA 532, a glass-flake filled epoxy solvent-free system. This protective coating system will with provide long term protection in this environment.
SCOPE
Identify damaged areas and check existing specification thickness
Bristle blast damaged surface area
Solvent wipe and square off using masking tape
Application of RS 500P in one coat to a nominal DFT of 100µm
Application of RA 532 in one coat to a minimum DFT of 250µm
PRODUCTS
OUTCOME
Chemcote was able to carry out the repairs to the internals of the heat exchanger vessel within the strict time frame provided by the client. This application will provide at least 10 years of corrosion free service.
RELATED CASE STUDIES
Fast Curing Abrasion Protection
Condition of surface before mechanical preparation RB 364 applied to spot abrasive blasted surfaces Pugmill externals Coating with InD Cote OVERVIEW: Chemcote’s specialist team
Split Case Salt Water Pump Refurbishment
Apply protection to all machined surfaces Application of 1st coat RB 364 Apply Ceram-Chem RP500 Ready to return to service for another 15+ years of
Composite Pipe Repair
Flange is barely attached Repairs commence Repairs using composite weave mat Coating complete OVERVIEW: A power station client required corrosion protection for a 30-plus