OVERVIEW: This 304 Stainless Steel Seawater/treatment water pool filtration system required provision of long term corrosion protection with a quick turnaround
INDUSTRY
ENVIRONMENT
Seawater/chlorinated – treatment water
SUBSTRATE
304 Stainless Steel
CHALLENGE
Short time frame requiring quick turnaround. Customer required provision of long term corrosion protection.
SOLUTION
Working around the clock and the application of proven RB 300 series, a glass flake filled vinyl ester with excellent resistance to chemical and abrasive protection.
SCOPE
Grind welds and sharp edges. Machine rebate to all flange faces to prevent crevice corrosion caused by misaligned gaskets.
Abrasive blast to Class 3 AS 1627.4 75micron profile (nominal) Apply of 2 coats of RB 300 Series to a DFT (dry film thickness) of 1200 microns.
Carry out QA including holiday test @ 8kV and confirm thickness.
Externals protected with 1 coat of RL 500PF
PRODUCTS
OUTCOME
Extremely fast turnaround and cure time – back in production in 3 days. Expected to exceed life requirement of 25 years, plus reduce maintenance cost in the future.
RELATED CASE STUDIES
Refurbishment of Basket Strainer
After fabrication repairs After abrasive blasting, pitting visible Finished 300 Series Vinyl Ester Internals nearing completion OVERVIEW: Customer required long term corrosion protection for
Duo Chek Valve
Masking and ready for abrasive blasting Application of multiple coats of RB364 internally Holiday testing to ensure coating continuity Coating complete OVERVIEW: Chemcote was
Pipe External Corrosion Protection
Existing corrosion, mech prep after UHPWB Application of spot primer Mid coat applied to affected areas After application of topcoat OVERVIEW: Chemcote was engaged