OVERVIEW: Chemcote was able to successfully refurbish this asset owner’s 5 year old FRP tanker to protect against Sodium Hypochlorite.
The surface was treated to neutralise the pH and composite repairs with Chemco’s glass flake reinforced vinyl ester were carried out.
INDUSTRY
ENVIRONMENT
13-15% Sodium Hypochlorite
SUBSTRATE
5 year old Fibre Reinforced Plastic Tanker
CHALLENGE
Asset owner required us to refurbish Fibreglass tanker carrying sodium hypochlorite refurbished after 5+ years in service. A hydro static testing on both compartments found a weep in the outlet areas. We removed deteriorated parts and searched for soft spots and voids to enable repair to progress.
SOLUTION
A large part of the repair process includes decontamination of the surfaces to be treated, one of which includes the pH neutralisation process
SCOPE
Assess internal fibreglass surfaces and structure, remove all noticeably deteriorated outlets and fill points
Whip abrasive blast and remove abrasive material
Create template from paper and carry out composite repairs
Application of RA 332 in 2 coats with a nominal thickness of 1,000μm
Application of RA 300 series in two coats
Post cure as required to Chemcote’s specifications for fibreglass tanker
Return all pipe work, fittings and man ways, carry out hydrostatic test to ensure all repairs carried out are to the required specifications
The success of this project has led the asset owner to nominate Chemco solutions and coating systems for all of the fibreglass tankers in the fleet
PRODUCTS
Chem-tect™ RB 332, Glass flake reinforced vinyl ester
OUTCOME
Chemcote’s solution has extended the life of this asset by 12-24 months, and delivered a 30% improvement in functioning. Continuous high performance is guaranteed until our review at the next planned outage.
RELATED CASE STUDIES
Fast Curing Abrasion Protection
Condition of surface before mechanical preparation RB 364 applied to spot abrasive blasted surfaces Pugmill externals Coating with InD Cote OVERVIEW: Chemcote’s specialist team
Split Case Salt Water Pump Refurbishment
Apply protection to all machined surfaces Application of 1st coat RB 364 Apply Ceram-Chem RP500 Ready to return to service for another 15+ years of
Composite Pipe Repair
Flange is barely attached Repairs commence Repairs using composite weave mat Coating complete OVERVIEW: A power station client required corrosion protection for a 30-plus