OVERVIEW: Salt Water Strainer had a large amount of external corrosion and severe localised pitting on the internals, particularly around the sealing ring.
Strainer was coated in time for re-assembly and will provide long term protection coupled with a non-toxic anti-foul coating to prevent marine growth.
INDUSTRY
ENVIRONMENT
Sea Water
SUBSTRATE
Salt Water Strainer
CHALLENGE
Inspection of the strainer found there to be a large amount of external corrosion and severe localised pitting on the internals, particularly around the sealing ring
SOLUTION
Due to the amount of metallic salts found after the preliminary abrasive blast it was necessary to hot wash the strainer components in an attempt to lower the salt content. Re-abrasive blasting was carried out and composite materials were chosen to rebuild the metal loss found on the tube plate support ring. Rebuilding this metal loss using our reinforced glass technique Chemcote ensured the tube plate had a flat area to rest on the mounting/sealing ring, in turn reducing costs and the additional time involved with machining.
SCOPE
Abrasive blasting to Chemcote standards
Application of RB 332 to the internals including the rebates
External coating application to System A which includes the application of RL 500PF @ 300um
Application of RC 500GTC Jade Green
Packaging and protection for transport
PRODUCTS
OUTCOME
Strainer was completed in time for re-assembly. RB 332 will provide long term protection coupled with the non-toxic anti-foul coating will prevent marine growth for a minimum of 5 years.
RELATED CASE STUDIES
22 year old pipes coated with glass flake vinyl ester
Internal lining in excellent condition Abrasive blast externals Recoating of externals Recoating of externals in basement OVERVIEW: The pipes were originally coated internally using
Premature Failure of 316L Stainless Steel Pipes
Severe pitting after 2 months in service After abrasive blasting Damaged internals rebuilt and coated Externally applied caution OVERVIEW: New 316L pipe failed after
Corrosion protection ensures a long life for a new 98% Sulphuric Acid Bund
Newly constructed bund Primer application Application of final coat Job completed OVERVIEW: Chemcote was contracted to apply acid protection to a newly constructed delivery