OVERVIEW: The asset owner approached us to provide protection for their for their new investment, 304 Stainless Steel tanks which would contain 13-15% Sodium Hypochlorite
INDUSTRY
ENVIRONMENT
13-15% Sodium Hypochlorite
SUBSTRATE
New 304 Stainless Steel
CHALLENGE
Asset owner required internal protection for their new ISOtainers which would be carrying sodium hypochlorite
SOLUTION
Abrasive blast and remove abrasive material
Application of RC 300 by spray application and stripe coating of all welds with a nominal thickness of 1,000μm
Confirm thickness and spark test
Apply top coat and post cure at 60degC for 6 hours
PRODUCTS
Chem-tect™ RC 300
Chem-tect ™ RA 364 glass flake reinforced vinyl ester
OUTCOME
The success of this project has allowed the asset owner long term peace of mind for their investment
RELATED CASE STUDIES
Fast Curing Abrasion Protection
Condition of surface before mechanical preparation RB 364 applied to spot abrasive blasted surfaces Pugmill externals Coating with InD Cote OVERVIEW: Chemcote’s specialist team
Split Case Salt Water Pump Refurbishment
Apply protection to all machined surfaces Application of 1st coat RB 364 Apply Ceram-Chem RP500 Ready to return to service for another 15+ years of
Composite Pipe Repair
Flange is barely attached Repairs commence Repairs using composite weave mat Coating complete OVERVIEW: A power station client required corrosion protection for a 30-plus