OVERVIEW: The asset owner approached us to provide protection for their for their new investment, 304 Stainless Steel tanks which would contain 13-15% Sodium Hypochlorite
INDUSTRY
ENVIRONMENT
13-15% Sodium Hypochlorite
SUBSTRATE
New 304 Stainless Steel
CHALLENGE
Asset owner required internal protection for their new ISOtainers which would be carrying sodium hypochlorite
SOLUTION
Abrasive blast and remove abrasive material
Application of RC 300 by spray application and stripe coating of all welds with a nominal thickness of 1,000μm
Confirm thickness and spark test
Apply top coat and post cure at 60degC for 6 hours
PRODUCTS
Chem-tect™ RC 300
Chem-tect ™ RA 364 glass flake reinforced vinyl ester
OUTCOME
The success of this project has allowed the asset owner long term peace of mind for their investment
RELATED CASE STUDIES
22 year old pipes coated with glass flake vinyl ester
Internal lining in excellent condition Abrasive blast externals Recoating of externals Recoating of externals in basement OVERVIEW: The pipes were originally coated internally using
Premature Failure of 316L Stainless Steel Pipes
Severe pitting after 2 months in service After abrasive blasting Damaged internals rebuilt and coated Externally applied caution OVERVIEW: New 316L pipe failed after
Corrosion protection ensures a long life for a new 98% Sulphuric Acid Bund
Newly constructed bund Primer application Application of final coat Job completed OVERVIEW: Chemcote was contracted to apply acid protection to a newly constructed delivery