OVERVIEW: The refinery column pump for storm water and effluent required repairs and surface coating to protect from corrosion. Corrosion pitting and erosion was evident in the suction bell & adjoining column and the wear spacer ring/housing.
We recommended rebuilding the internal diameters affected by erosion corrosion to extend column pipe life and return pump to original efficiency
INDUSTRY
ENVIRONMENT
Storm Water, Effluent from Refinery
SUBSTRATE
Column pump
CHALLENGE
Column pump repairs were required and the surface coated to protect from corrosion. Corrosion pitting was evident in the suction bell & adjoining column. Erosion/corrosion was taking place in the wear spacer ring/housing.
SOLUTION
We recommended rebuilding the internal diameters affected by erosion corrosion to extend column pipe life and return pump to original efficiency
SCOPE
Abrasive blast to AS.1627.4 to class 2.5
Masking and protection of critical shaft tolerances
Pitting filled to allow smooth transition and prevent coating defects
Application of RA 532 internal & external
Pit-filled areas within impeller housing to ensure smooth finish
Application of RA 532 at a nominal thickness of 200 µm internal & external
Application of RP 500 internal
Application of Luxathane R ‘N35’ external
OUTCOME
The column pump repairs were timely, returning the unit to service within a week. A new replacement pump had a lead time of 16 weeks. The client was extremely happy thanks to the experienced Chemcote team and the exceptional qualities of the Chemco range.
RELATED CASE STUDIES
22 year old pipes coated with glass flake vinyl ester
Internal lining in excellent condition Abrasive blast externals Recoating of externals Recoating of externals in basement OVERVIEW: The pipes were originally coated internally using
Premature Failure of 316L Stainless Steel Pipes
Severe pitting after 2 months in service After abrasive blasting Damaged internals rebuilt and coated Externally applied caution OVERVIEW: New 316L pipe failed after
Corrosion protection ensures a long life for a new 98% Sulphuric Acid Bund
Newly constructed bund Primer application Application of final coat Job completed OVERVIEW: Chemcote was contracted to apply acid protection to a newly constructed delivery